Delhi Schedule of Rates Civil - - Ebook download as PDF File .pdf), Text File .txt) or read book online. Delhi Schedule of Rates Civil - storage and retrieval system, without permission, in writing, from the Director General, CPWD, New Delhi This Analysis of Rates for Delhi is prepared for . Delhi Schedule of Rates- includes the existing items of DSR with The cost index for DSR is with reference to Delhi Plinth Area Rates.


Delhi Schedule Of Rates 2014 Pdf

Author:KEIRA HERNON
Language:English, Dutch, Hindi
Country:Nepal
Genre:Fiction & Literature
Pages:181
Published (Last):24.08.2016
ISBN:531-9-78365-285-1
ePub File Size:17.89 MB
PDF File Size:10.28 MB
Distribution:Free* [*Registration needed]
Downloads:22546
Uploaded by: THEOLA

This Delhi Schedule of Rates (E & M) is prepared for the use of CPWD. . The Delhi schedule of Rates (E&M) now replaces the Delhi Schedule of. This Analysis of Rates for Delhi is prepared for the use of CPWD. Analysis of Rates for Delhi, is published in two volumes i.e. Delhi. This Analysis of Rates for Delhi is prepared for the use of CPWD. Analysis of Rates for Delhi, is published in two volumes i.e. volume I & II as.

Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Extra labour for lifting materials: Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by mechanical means.

Amount Extra for providing and placing in position 2 Nos 6 mm dia M. S bars at every third course of half brick masonry. Details of cost for 10 sqm 6mm dia. Tile brick masonry with common burnt clay tile bricks of class designation 10 in foundation and plinth in: Tile brick masonry with common burnt clay machine moulded tile bricks of class designation Machine moulded common burnt clay tile bricks of class designation Tile brick masonry with common burnt clay tile bricks of class designation 10 in superstructure above plinth level up to floor V level in cement mortar 1: Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Extra labour for lifting of materials Coolie Cost of sclafolding.

Mortars Sundries Centering and shttering area same as in item number 6. Tile brick masonry with common burnt clay F. Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Extra labour for lifting of material Above floor two level upto floor five level Coolie Unit Quantity Nos Mortars Sundries and shuttering Centering and shuttering Area same as in item no 6.

Code No Description 3. Brick work Extra for delay due to fine work cum L. Brick work with bricks of class designation 75 in cement mortar 1: The quantity will be calculated by multiplying the depth measured from sub-soil water level upto the centre of gravity of brick work unnder sub-soil water with the quantity of brick work in cum executed under the sub-soil water. Code No Description 6.

Code No Description Unit Details of cost for 1 cum. S non modular bricks of class designation 7. Extra labour due to slow progress Mason brick layer 1 st class Mason brick layer 2nd class Beldar Coolie day day day day Quantity 0. Modular common burnt clay bricks of class designation 7. For selection of bricks in superstructure Beldar Mason brick layer 1 st class day day 0.

Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Extra labour element required for lifting of material above floor two level upto floor five level Coolie Sundries Quantity Nos Common burnt clay modular bricks class designation Machine moulded common burnt clay FPS non modular bricks of class designation Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Scaffolding Extra labour element required for lifting of materials above floor two level upto floor V level 0.

Fly ash bricks conforming to I. Calcium Silicate Bricks machine moulded conforming to I. S Cement mortar 1: Extruded burnt flyash clay sewer bricks conforming to I. Mortars Carriage of bricks Sundries Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Scaffolding Extra labour element required for lifting of materials above floor two level upto floor V level 0. The rate includes providing and placing in position 2 Nos 6 mm dia M. Autoclaved aerated cement AAC blocks Cement mortar 1: Reinforced cement concrete work kilogram Quantity Gypsum blocks will have a minimum compressive strength of 9.

Gypsum panel X X mm size sqm Mason average day Beldar day Bhisti day Sundries L.

Schedule of Rates

Say Mason brick layer 1 st class Mason brick layer 2nd class Coolie Bhisti Extra labour elemant required for lifting of material above floor two level upto floor five level. Mason for plain stone work 2nd class Beldar Coolie Bhisti Cement concrete 1: Mason for plain stone work 2nd class Coolie day day Quantity 0.

Cement mortar l: Masonry work first sort. Mason for plain stone work 2nd class Beldar Coolie Bhisti Extra labour for lifting of material upto floor five level. Coolie Sundries. Labour for cutting and dressing Mason for plain stone work 2nd class Coolie cum 0. Mason for plain stone work 2nd class day 0. Quantity 2. Mason for plain stone work 2nd class Blacksmith 1 st class Beldar Coolie Bandhani Bhisti Scaffolding Mortar for laying and pointing Centering and shuttering Extra for using white cement Extra labour for lifting of material upto floor five level 0.

Add wastage Code No Description Unit Mortar for laying and pointing Centering and shuttering Extra for using white cement Extra labour for lifting of material upto floor five level 0. Code No Description Unit Extra labour for lifting of material upto floor five level 0.

Mason for plain stone work 2nd class Blacksmith 1 st class Beldar Coolie Bandhani Bhisti Scaffolding Mortar for laying and pointing Extra labour for lifting of material upto floor five level 0. Code No Description Unit Details of cost for 10 cudm or 0. Quantity 6.

Quantity 8. Brace -3x2x2. Reinforced cement concrete work Unit Quantity 10 cudm Carpenter 2nd class Beldar Sundries Less Cost of shuttering etc.

Mason for plain stone work 2nd class Blacksmith 1 st class Beldar Coolie Bandhani Bhisti Scaffolding Mortar for laying and pointing Extra labour for lifting of materials upto floor V level 0. Code No Description Unit Blacksmith 1 st class Beldar Coolie Bandhani Bhisti Scaffolding Mortar for laying and pointing Extra labour for lifting of materials upto floor V level 0. Mason for plain stone work 2nd class 0.

Exposed face fine dressed with rough backing. Mason for plain stone work 2nd class Bandhani Beldar Coolie Bhisti Cutting marble or sand stone slab up to 50 mm thick by mechanical device Scaffolding Mortar for laying and pointing Rate as per Item Number 3.

To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately: Red sand stone. Mason for plain stone work 2nd class Bandhani Beldar Coolie Bhisti Cutting marble or sand stone slab up to 50 mm thick by mechanical device Scaffolding Rate as per Item Number 3. Exposed face machine cut and table rubbed with rough backing. Stainless steel cramp 10x0.

Mortar for pointing 1: Mortars Sundries including hire charges of hand cut machine etc cum L. Mortars Pigment cum L. Labour for dressing: Brick work in triangular gap above cover with bricks of class designation 7. Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1: White sand stone: With common burnt clay F. Details of cost for a chajja of 2.

Labour for dressing Mason for plain stone work 2nd class Labour for dressing Anchoring steel bars 12mm dia. Mortars Pigment Extra cost of white cement. Mason for plain stone work 2nd class Beldar Scaffolding and sundries etc. Brick work in triangular gap above cover with bricks of class designation 5 in cement mortar 1: Brick work. Details of cost for 2. Taking 2. Labour for dressing Mason for plain stone work 2nd class Mortar for pointing 1: Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1: Details of cost for window 1.

Red stone brackets chisel dressed 30mm average thickness over all width of brackets 0. Providing and fixing red sand stone brackets 55x Details of cost for 1 bracket Quantity of stone for 1 bracket 1 x 55 x Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in cement mortar 1: Code No Description Details of cost for cornices 30cm long 30cm deep and 7.

Stone work plain ashlar cyclopean 3x3x0. Stone work Extra for using white cement Extra labour for making the cornices Mason for plain stone work 2nd class Beldar. Providing and fixing stone jali 40 mm thick throughout in cement mortar 1: Details of cost for 1 cum Extra labour due to slow progress Mason brick layer 1 st class Mason brick layer 2nd class Beldar Coolie. Deduct for embed within 3x0. White sand stone slab 40 mm thick un-dressed 75mm thick 3x0.

Mortars Cutting chases and making good with mortar after insurting stone etc. Rate as per Item Number Mason for ornamental stone work 1 st class Mason for plain stone work 2nd class Beldar Bhisti Sundries and scaffolding brushes etc. Stone work machine cut edges veneer work for wall lining upto 10 m height, backing filled with a grout of 12 mm thick cement mortar 1: To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately 7.

Mortars Cement mortar for pointing. Mason for plain stone work 2nd class Beldar Coolie Skilled Beldar for floor rubbing etc. Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1: Add 2. Mortars Portland Cement slurry 3. Mason brick layer 1 st class Beldar Granular sand particles mixed with araldite to be pasted on each side to form interlocking arrangement with cement plaster Sundries.

Details of cost for 10 sqm Analysis same as Item Number Extra for stone work for wall lining on exterior walls of height more than 10 m from ground level for every additional height of 3 m or part there of.

The steel frame work, stainless steel cramps and pins etc. Red sand stone gang saw cut 30 mm thick Cutting marble or sand stone slab up to 50 mm thick. Providing and fixing structural steel frame for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone on walls at all heights using M. The frame work. Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid.

Code No Description. Angle iron 50x50x6mm16x0. Finishing For labour scaffolding etc. Code No Description Unit Quantity each Mortars White cement mortar 1: Hand Grinder for mirror polish day 2. Code No Description 8. Machine for rubbing of floors Beldar Bhisti Sundries grease. Gun Metal cramp 10x0. Stainless steel cramp10x0. Mortars Labour for fixing in position 8. Fitter grade 1 day Beldar day Hire and running charges for hand drill machine Sundries. Agaria Marble Stone 1 x 0. Add wastage.

Granite Stone 1x0. Fire Red or Dark Emperadore etc. Mortars White Cement Slurry 3.

Marble stone work for wall lining veneer work including dado. Code No Description Unit Table rubbed polished stone 18mm thick 75x50cm Granite stone. Rosso verona. Mortars tonne cum 0. Cherry Red. Mason brick layer 2nd class Beldar day day 1.

PREVIOUS EDITIONS

Flamed finish granite stone slab Jet Black. Cat Eye or equivalent. Elite Brown. Superior class teakwood such as Dandeli Balarshah or Malabar 2x Salwood 2x Hollock wood 2x Carpenter 1 st class Carpenter 2nd class Beldar 10 cudm cum Carpenter 2nd class day 1. Hollock wood in scantling Carriage of timber Kiln seasoning of timber Chemical treatment Unit 10 cudm cum cum L.

Second class teak wood Code No Description Unit Details of cost for chowkhat of a door Teak wood Styles 4xx Second class teak wood 9. Carpenter average Beldar day day Quantity 0. Hollock wood Styles 4xx Teak wood Styles: Hollock wood Styles 4xxl0. Carpenter average day 1. Lock rails 1x I or graded wood particle board FPT-I. Bright finished or black enameled mild steel butt hinges x58x1.

Grade 1. Carpenter average day Beldar day Sundries L. II marked: I or graded wood particle board FPT. Fittings Bright finished or black enameled mild steel butt hinges x58x1. Type II marked: Panels 4x Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Carpenter 1 st class Sundries day L. Plywood 9mm thick 4x Carpenter 1 st class day 0. Grade I. Type II. Coir veneered board 12mm thick 4x Area of opening for glass panes excluding portion inside rebate shall be measured.

Code No Description Unit Carriage of shutters Fittings Bright finished or black enameled mild steel butt hinges x58x1. Float glass sheet of nominal thickness 5. Shutter area to be measured. Bright finished or black enameled mild steel butt hinges 6. Carpenter 1 st class day 2. Code No Description Unit lock and bottom rail-2x Teak wood second class styles 4 x x 9. Type II exterior grade IS: Block board construction flush door with teak wood ply on both faces 35 mm thick Carriage of door Stainless steel butt hinges heavyweight x60x2.

Block board construction flush door with teak wood ply on both faces 30 mm thick Carriage of door Stainless steel butt hinges heavyweight x60x2. Piano hinges IS: For fixing shutter and fittings Carpenter average Beldar day day 0. Block board construction flush door with commercial ply on both faces 30 mm thick Carriage of door Fittings for a door 2. Block board construction flush door with commercial ply on both faces 35 mm thick Carriage of door Fittings for a door 2.

For flush door shutters Extra for providing teak veneering on one side instead of commercial veneering sqm Quantity 1. Block board construction flush door with commercial ply on both faces 25 mm thick Carriage of door Fittings for a door 2. For fixing shutter and fittings Carpenter average Beldar sqm L.

On one side only Code No Description Carpenter 1 st class day 1. Teak wood 2nd class Styles 4xx9. Styles 4xx9. Sheesham Wood Styles 4 x x 9. Second class Teak wood Styles 4xx9. Hollock wood Styles 4xx9. Sheesham wood Styles 4 x x 9. Code No Description Unit Bright finished or black enameled mild steel butt hinges x58x1.

Say 44 cudm Hollock wood in planks 10 cudm Say 14 cudm Second class teak wood in scantling Carriage of timber Cement mortar 1: Expandable fastener with plastic sleeve and M.

Code No Description Unit Labour for drilling holes and making good etc. Unit Quantity each L. For planning and fixing Carpenter 1 st class day 2. Say cudm Second class teak wood in planks 10 cudm Wood and PVC work each Teak wood 2nd class 10x0. Finishing sqm Wood and PVC work Priming coat Say cudm Second class teak wood in planks Extra for selected planks of second class teakwood Carriage of timber Second class teak wood plugs including cutting brick work and fixing in cement mortar 1: Unit Quantity 10 cudm Finishing Second class teak wood 10x0.

Unit day day day L. Priming coat Priming coat Unit sqm L. Finishing Rawl plug 50 mm designation 10 nos Labour for drilling holes steel tape sundries 10 cudm cum Hollock wood 5x5. Code No Description Details of cost for 10 sqm. Carpenter 1 st class Beldar Mistry 20mm nails without head for fixing ply Painting with ready mixed priming coat ISI marked IS: Teak wood Ilnd class in planks x5x1. For plaining. Say 3. Finishing 10 cudm 3. For planing.

Hollock wood x5x1. Teak wood Ilnd class in planks x5x 2. Say 5. Say 0. Flat pressed 3 layer and graded particle board medium density Grade 1 conforming to IS: Teakwood Ilnd class Jaffri xx1.

Carpenter 2nd class day 0. Pipe 20 mm dia. Brackets for curtain rod 20 mm metre each 1. Flat 10 cm long fixed to pelmet with hollock wood cleats of size mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc.

Non decorative veneer on both sides Code No Description Chromium plated Brass curtain rod 12 mm dia 1. Chromium plated Brass curtain rod 20 mm dia 1. Brackets for curtain rod 25 mm Screws Carriage Rawl plug 50 mm designation 10 nos Labour including fixing rawl plug Sundries metre each L.

Nickel plated M. Sundries metre each L. Brackets for curtain rod 20 mm Screws Carriage Rawl plug 50 mm designation 10 nos Rawl plug 50 mm designation 10 no. Say 4 kg. Expended metal x60mm mesh 3. Hard drawn steel wire fabric x60mm mesh 3. Wire gauge x60mm mesh 3. Difference in cost of Hard drawn steel wire fabric Float glass sheet of nominal thickness sqm 1. Bright finished or black enameled mild steel butt hinges x65x2.

Bright finished or black enameled mild steel butt hinges 75x47x1. Bright finished or black enameled mild steel butt hinges 50x37x1. Oxidised mild steel butt hinges x65x2. Oxidised mild steel butt hinges x58x1. Oxidised mild steel butt hinges 75x47x1.

Oxidised mild steel butt hinges 50x37x1. Oxidised mild steel parliamentary hinges xx27x2. Oxidised mild steel single acting spring hinges mm each Oxidised mild steel screws 50 mm Nos Carriage of material L. Oxidised mild steel parliamentary hinges 75xx20x2. Oxidised mild steel single acting spring hinges mm Oxidised mild steel screws 40 mm Carriage of material each Oxidised M. Oxidised mild steel sliding door bolt x16 mm each Carpenter 2nd class Quantity each Barrel type with necessary screws etc.

Carpenter 2nd class each Nos L. Code No Description Details of cost for 10 nos. Oxidised mild steel pull bolt lock locking bolt of size 85 mm x 42 mm with screws. Safety chain with necessary fixtures for doors. Stainless steel butt hinges 75x47x1. Stainless steel butt hinges heavy weight x64 x 2. Stainless steel butt hinges 50x37x1. Wire in 15 mm dia G. Metre 35 5. Metre 99 5. Metre 23 5. Metre 86 5. Each 6. Each 72 6. For horizontal run Metre 6. For vertical run Metre 6. For horizontal run Metre 68 6.

For vertical run Metre 98 6. For horizontal run Metre 35 6. For vertical run Metre 72 6. Each 71 6. Metre 6. Each Set Bolt, nuts and straps etc. Spindle and nuts etc. Set 76 Set 78 Set 36 Kg 88 Kg Kg 89 Wire No. Kg 18 Each 96 Each 32 Each 64 Each 67 Each 78 Each 49 Each 73 Kg 38 Set 73 Cum Cum 63 Sqm Sheet for pipes upto mm dia.

And from minimum 7mm thick MS sheet for pipes of mm dia and above. Metre Sqmtr Union 25 mm nominal bore G. Union 32 mm nominal bore G. Union 50 mm nominal bore G. Description R. Description Hollock ballies mm diameter Oxidised mild steel pull bolt lock locking bolt of size 85 mm x 42 mm with screws. Non Staining ml Weather Sealant. Size 10 mm x mm Carben Steel galvanised dash fastner min 5 micron of 10 mm dia double threaded 6. Description Carben Steel galvanised dash fastner min 5 micron of 10 mm dia double threaded 6.

Size 10 mm x 80 mm Carben Steel galvanised dash fastner min 5 micron of 10 mm dia double threaded 6. Size 10 mm x mm Common burnt clay F. Brass union 40mm dia C. Description C.

Description S. Slotted Cowl Terminal Guard 75 mm S. Slotted Cowl Terminal Guard mm S. Box for ceiling fan Pulley 40 mm dia Aluminium primer Red oxide Zinc chromate primer Copper acetate Hydrochloric acid Copper chloride Copper nitrate Ammonium chloride Mobil oil White marble slab Makrana second quality plain veined 18 mm thick Pink marble slab plain 18 mm thick Udaypur green marble slab plain 18 mm thick Black Zebra marble slab plain 18 mm thick Sand zone V Jamuna Brass mm mortice latch and lock with 6 levers without pair of handles Pair of Anodised Aluminium lever handles for mm mortice latch and lock Vitreous china flat back wash basin x mm Vitreous china 10 litres low level cistern without fittings Vitreous china 10 litres low level cistern with fittings F.

Description Galvanised Steel perimetre Channel Size 20x27x30x0. Chromium plated brackets curtain rods Acid Proof cement M. Brackets for curtain rod 20 mm Nickel plated M. Butt hinges x90x4 mm Brackets for curtain rod 25 mm Oxidised mild steel screws 35 mm Mild steel conduit pipe heavy type ISI marked mm dia Mild steel conduit pipe heavy type ISI marked mm dia Rolling shutters of 80x0. Hydraulic door closer tubular type Aluminium section body Oxidised M.

Tee mm Expanded polystyrene type N- Normal Expanded polystyrene type - SE Stainless steel kitchen sink - with drain board bowl depth mm Stainless steel kitchen sink - with drain board x mm bowl depth mm Stainless steel kitchen sink - with drain board x mm bowl depth mm Stainless steel kitchen sink - with drain board x mm bowl depth mm Stainless steel kitchen sink - without drain board x mm bowl depth mm Stainless steel kitchen sink - without drain board x mm bowl depth mm Stainless steel kitchen sink - without drain board x mm bowl depth mm Coloured Orissa pattern W.

Table rubbed polished stone 18 mm thick 75x50cm Agaria Marble stone - 18 mm thick Table rubbed polished stone 18mm thick 75x50cm Granite stone18 mm thick Vertical load testing initial of piles in accordance with IS: Brass bibcock 15 mm C.

Brass long nose bibcock 15 mm C. Brass long body bibcock 15 mm C. Brass stop cock concealed 15 mm C. Brass angle valve 15 mm Pressed clay tiles 20mm thick x mm size Plain ceiling tiles BWP type phenol formaldehyde synthetic resin bonded xx12 mm Semi perforated ceiling tiles xx12 mm 25 mm thick particle board.

Cadmium plated full threaded steel screws 30x4 mm dia Aluminium washer 2 mm thick 15 mm dia 12 mm M. S of S. R quality mm dia Rubber Gaskets Conforming to I. R quality mm dia Rubber Gaskets Conforming to 1. R quality mm dia Ductile Iron K - 12 specials suitable for push on jointing up to mm dia Ductile Iron K - 12 specials suitable for push on jointing over mm dia Ductile Iron specials suitable for mechanical jointing as per I.

Pipe of Class B conforming to I. Description Ductile Iron Specials suitable for mechanical jointing as per I. Pipe specials suitable for mechanical joint as per I.

Pipe Specials suitable for mechanical joint as per I. S bail plug mm dia M. Description Screwed double flanged centrifugally cast spun C. Ceramic Glazed Tiles 1st quality x in all shades designs except White. Grating square slit mm P. Rectified Ceramic Glazed Tiles 1st quality x mm or more in all shades designs except White.

Fume Red Brown etc.

Stop cock concealed 15 mm 15 mm nominal bore and 30 cm length PVC connection pipe with P. Fume Red brown etc. Nuts 15 mm nominal bore and 45 cm length PVC connection pipe with P. Rectified Ceramic Glazed Tiles 1st quality x mm or more in all shades designs White.

Description uPVC slotted pipe mm dia as per IS: Urinal cock 15 mm dia P. Nuts P.

Delhi Schedule of Rates Civil - 2014

Bib cock with nozzle 15 mm P. Description P. Calcium Silicate tegular edged celling tiles x mm and 15 mm thick Galvanised Steel main Tee ceiling section Size 24x38x0. Metal Primer U. Description Stainless steel butt hinges 50x37x1. Description Poly propylene. PVC coated to outer dia 5 mm sqm M sqm Kerb stone M. Single piece extruded door frame of profile size 50 mm x 47 mm with wall thickness of 5 mm 35 mm thick factory made solid panel PVC door shutter of single piece extruded profile non decorative finished Matt finished 35 mm thick factory made solid panel PVC door shutter of single piece extruded profile decorative finished wood grain finished Stainless steel wire guage Grade aperture 1.

Sheet of section mm x 57 mm duly filled with vermuculite based concrete mix Fire rated door shuttere made with 16 SWG G. U beading of 16 SWG G. Description Female Threaded Elbow 90 for Driving end tubes for diaphragm wall mm dia.

Sundries Nos pair kg sqm sqm L. Unloading and stacking Note: Ductile Iron pipes k7 mm dia Cast iron pipes mm dia Cast iron ptpes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia Cast iron pipes mm dia BASIC RATES: The length of S.

Stainless Steel pipes below mm dia and other heavy materials tonne Steel cylinder. Steel cylinders. The length of socketed pipes shall be measured exclusive of internal depth of sockets The length of asbestos cement pipes shall be measured exclusive of internal depth of sockets.

Description 1 2 1. No deduction shall be from carriage rates for direct unloading or loading. And similar heavy materials. Tonne Description 2. Excavating trenches of required width for pipes. Extra for excavating trenches for pipes. Rate is over corresponding basic item for depth upto 1. All kinds of soil 2. Measurements to be taken of the face area timbered: Measurements to be taken of the face area timbered.

Face area of the timber permanently left to be measured. Close timbering in trenches including strutting. Open timbering in trenches including strutting and shoring complete measurements to be taken of the face area timbered: Face area of timber permanently left to be measured.

Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish.

The extra percentage rate is applicable in respect of each item but limited to quantities of work executed in these difficult conditions. The unit. The depth shall be reckoned correct to 0. Felling trees of the girth measured at a height of 1 m above ground level. Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. Filling available excavated earth excluding rock in trenches.

Extra for every additional lift of 1.

Deduct for disposed soil not levelled and neatly dressed. Unit Filling with available fly ash and earth excluding rock in trenches or embankment in layers each layer should not exceed 15 cm.

Supply and stacking of Fly ash conforming to IRC. These rates are exclusive of water charges. All work up to plinth level: SITU 4. Code No.. Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1: Providing and laying damp-proof course 40 mm thick with cement concrete 1: Providing and laying damp-proof course 50 mm thick with cement concrete 1: Precasting and placing in position mm dia Bollards mm high of required shape, including providing M.

Pipe Sleeve 50 mm dia mm long in the Bollard and M. Pipes 40 mm dia and mm long with xx6mm M. Extra for concrete work in superstructure above floor V level for each four floors or part thereof. Note for item No. The depth of centre of gravity shall be reckoned correct to 0.

Making plinth protection 50 mm thick of cement concrete 1: Extra for addition of synthetic Polyester triangular fibre of length 12mm, effective diameter microns and specific gravity of 1. Per Bag of 50 Kg of cement. Providing and laying in position ready mixed plain cement concrete, using fly ash and cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.

Uniform blending with cement is to be ensured in accordance with clauses 5. Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.

Posts and Struts sqm CAST R.. Description 5. Providing and fixing in position copper plate as per design for expansion joints. Extra for rendering smooth the top of suspended floors. Providing and fixing sheet covering over expansion joints with iron screws as per design. The quantity will be calculated by multiplying the depth measured from the subsoil water level up to the centre of gravity of the R.

Note For Item No. Providing and laying in position ready mixed M grade concrete for reinforced cement concrete work. Providing and placing in position precast reinforced cement concrete waffle units.

The length of the bars in which coupler is to be provided should not be less than 4 metre. The above item shall be used judiciously where specified quality of Fly Ash is available for mixing in concrete.

The joints system will be of extruded aluminum base members. Uniform blending with cement to be ensured in accordance with clauses 5. The joints shall be of extruded aluminum base members with. The joints shall be of extruded aluminum base members.

Material shall confirm to ASTM The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement.

The Joint System shall resists damage or deterioration from the impact of falling ice. The Self — centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement.

Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in. The cost of hold fast and cc block of 1: The frame shall be measured in running meter correct to two places of decimal.

Cement content considered in this item is Kg. Reinforcement shall be measured and paid separately. S Nos Type 3 grade 1 sqm Description Machine moulded common burnt clay FPS non modular bricks of class designation Brick work with common burnt clay machine moulded perforated bricks of class designation Brick work in gauged arches in superstructure above plinth level and upto floor five level in cement mortar 1: Providing half brick masonry with common burnt clay F.

Brick work 7 cm thick with common burnt clay F. Extra for additional cost of centering for arches exceeding 6m span including all shuttering. Brick work in plain arches in superstructure above plinth level and upto floor five level including centering and shuttering complete for span up to 6 metres with common burnt clay F.

Description 6. The quantity will be calculated by multiplying the depth measured from sub. Half brick masonry with non modular fly ash bricks of class designation Providing and laying autoclaved aerated cement blocks masonry with mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1: The rate includes providing and placing in position 2 Nos 6 mm dia M.

Deleted Providing and laying Gypsum panel partitions mm thick with water proof Gypsum panels of size xx mm. Deleted Deleted Brick edging 7cm wide Gypsum blocks will have a minimum compressive strength of 9. Cement mortar 1: Exposed face machine cut and table rubbed with rough backing. To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately: White sand stone.

Providing and fixing sloping chajja of stone 40 mm thick and upto 80 cm wide beyond the wall as measured along the slope in cement mortar 1: To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately. The steel frame work. Only structural steel frame work shall be measured for the purpose of payment. The frame work shall be fixed to the wall with the help of M. Portland Cement day tonne Description 8.

Vanities etc. Providing and laying flamed finish Granite stone flooring in required design and patterns. Cherry Red. Elite Brown. Fire Red or Dark Emperadore etc. Marble stone work for wall lining veneer work including dado. Cat Eye or equivalent. Flamed finish granite stone slab Jet Black. Rosso verona. Brackets for curtain rod 25 mm Oxidised mild steel screws 35 mm Mild steel conduit pipe heavy type ISI marked mm dia each 8.

Brackets for curtain rod 20 mm each 8. Description Mild steel conduit pipe heavy type ISI marked mm dia Rawl plug 50 mm designation 10 nos Teak wood lipping of size 25x3 mm in pelmets Flat pressed 3 layer and graded particle board medium density Grade 1 conforming to IS: I as per IS: Type II conforming to IS: Sheet of section mm x 57 mm duly filled with vermuculite based concrete mix metre Single piece extruded door frame of profile size 50mm x47mm with wall thickness of 5 mm 35 mm thick factory made solid panel PVC door shutter of single with extruded profile non decorative finished Matt finished 35 mm thick factory made solid panel PVC door shutter of single piece extruded profile decorative finished wood grain finished metre Wood work items may be substituted with available species of wood as per direction of Engineer-in-charge for which rates shall be derived from the relevant items.

Providing wood work in frames of false ceiling. Grade 1. II marked: I or graded wood particle board FPTI. Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick: Type II marked: Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors.

Grade I. Type II. Grade Type II IS: Deduct for providing pin headed glass panes instead of ordinary float glass panes weighing 4 mm thick in doors. Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors. Providing and fixing glazed shutters for doors.

Area of opening for glass panes excluding portion inside rebate shall be measured 9. Area of opening for glass panes excluding portion inside rebate shall be measured.

Description 9. Shutter area to be measured. Piano hinges IS: Type II exterior grade IS: Extra for providing vision panel not exceeding 0. Providing and fixing wire gauge shutters using galvanized M. Providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised M.

ISI marked IS: Providing and fixing 18 mm thick. Pipe 20 mm dia. Flat 10 cm long fixed to pelmet with hollock wood cleats of size mm x 40 mm x 40 mm on both inner side of pelmet and rawl plugs 75 mm long etc. Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts.

Providing and fixing fly proof galvanized M. Providing and fixing expanded metal 20x60 mm strands 3. Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.

Providing beams including hoisting. In coastal areas. Barrel type with necessary screws etc. Safety chain with necessary fixtures for doors. Providing and fixing bright finished brass mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. Providing and fixing bright finished brass night latch of approved quality including necessary screws etc.

Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer having brand logo with ISI. Providing and fixing bright finished brass handles with screws etc.

Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI. Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc.

Description mm. Providing and fixing chromium plated brass casement stays straight peg type with necessary screws etc. Providing and fixing chromium plated brass handles with necessary screws etc. ISI marked. Providing and fixing bright finished brass mm mortice latch and lock.

Providing and fixing aluminium handles.

Aluminum hinges shall not be used in wooden shutters. Providing and fixing aluminium sliding door bolts. Providing and fixing 50 cm long aluminium kicking plate of size x3. Bending Strength kg.Code No Description Unit 48mm studx34x36x0. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multi-cellular to facilitate movement.

Stainless steel wire guage Grade aperture 1. Angle iron 50x50x6mm16x0.

Code No Description Unit Details of cost for 10 nos. Ochini Chandrasena. Considering bitumen using Brass long body bibcock 15 mm each I steel 0.